Delek Refining, Limited v. OSHC , 845 F.3d 170 ( 2016 )


Menu:
  •      Case: 15-60443   Document: 00513815691    Page: 1   Date Filed: 12/29/2016
    IN THE UNITED STATES COURT OF APPEALS
    FOR THE FIFTH CIRCUIT
    United States Court of Appeals
    Fifth Circuit
    No. 15-60443                       FILED
    December 29, 2016
    Lyle W. Cayce
    DELEK REFINING, LIMITED,                                           Clerk
    Petitioner,
    v.
    OCCUPATIONAL SAFETY AND HEALTH REVIEW COMMISSION;
    THOMAS E. PEREZ, SECRETARY, DEPARTMENT OF LABOR,
    Respondents.
    On Petition for Review of an Order of the
    Occupational Safety and Health Review Commission
    Before DENNIS, ELROD, and GRAVES, Circuit Judges.
    JENNIFER WALKER ELROD, Circuit Judge:
    Delek Refining, Limited purchased an oil refinery in Tyler, Texas from
    Crown Central. After the transfer in ownership, the Occupational Safety and
    Health Administration conducted an inspection and issued a citation for
    violations of its process safety management rules, which govern an employer’s
    responsibility to inspect, and to develop inspection and recording regimes for,
    machinery that handles large volumes of hazardous chemicals. Because we
    conclude that the citations for Items 4 and 12 are barred by the six-month
    statute of limitations in 29 U.S.C. § 658(c), we VACATE the citations for those
    items. Because we also conclude that the regulations relevant to the citation
    Case: 15-60443         Document: 00513815691          Page: 2     Date Filed: 12/29/2016
    No. 15-60443
    for Item 8 are ambiguous and the Secretary’s interpretation is reasonable, we
    AFFIRM the citation for Item 8.
    I.
    Delek purchased an oil refinery located in Tyler, Texas from Crown
    Central and took possession on April 29, 2005. Beginning in February 2008,
    the Occupational Safety and Health Administration conducted a four-month
    inspection of the refinery and issued a citation on August 18, 2008, finding
    violations of 29 C.F.R. § 1910.119—an OSHA regulation governing “Process
    Safety Management of Highly Hazardous Chemicals”—and other regulations
    that are not at issue here. Section 1910.119 imposes a series of requirements
    on employers which are intended, according to that section’s purpose
    statement, to “prevent[ ] or minimiz[e] the consequences of catastrophic
    releases of toxic, reactive, flammable, or explosive chemicals . . . [that] may
    result in toxic, fire or explosion hazards.” 
    Id. Delek petitions
    for review of citation Items 4, 8, and 12. Item 4 alleges a
    failure to resolve open findings and recommendations identified during process
    hazard analyses that occurred in 1994, 1998, 1999, 2004, and 2005—prior to
    Delek purchasing and taking possession of the refinery. 1 Item 8 alleges an
    1   The regulations underlying the citation for Item 4 provide:
    (5) The employer shall establish a system to promptly address the team’s
    findings and recommendations; assure that the recommendations are resolved
    in a timely manner and that the resolution is documented; document what
    actions are to be taken; complete actions as soon as possible; develop a written
    schedule of when these actions are to be completed; communicate the actions
    to operating, maintenance and other employees whose work assignments are
    in the process and who may be affected by the recommendations or actions.
    (6) At least every five (5) years after the completion of the initial process hazard
    analysis, the process hazard analysis shall be updated and revalidated by a
    team meeting the requirements in paragraph (e)(4) of this section, to assure
    that the process hazard analysis is consistent with the current process.
    (7) Employers shall retain process hazards analyses and updates or
    revalidations for each process covered by this section, as well as the
    2
    Case: 15-60443         Document: 00513815691         Page: 3     Date Filed: 12/29/2016
    No. 15-60443
    inadequate monitoring and inspection regime for certain equipment involved
    in process safety management. 2 Specifically, the Secretary alleges that Delek
    failed to inspect a positive pressurization unit, which pressurizes the control
    room for the fluid catalytic cracking unit and detects the presence of hazardous
    vapors. Item 12 alleges that Delek failed to determine and document a
    response to the findings of a 2005 compliance audit in a timely manner. 3 As
    with Item 4, the audit at issue in Item 12 was conducted before Delek took
    possession of the refinery.
    The Secretary of Labor brought an enforcement action against Delek for
    these and other violations. The administrative law judge affirmed seven of the
    documented resolution of recommendations described in paragraph (e)(5) of
    this section for the life of the process.
    29 C.F.R. § 1910.119(e)(5)–(7).
    2   The regulations underlying the citation for Item 8 provide:
    (1) Application. Paragraphs (j)(2) through (j)(6) of this section apply to the
    following process equipment: (i) Pressure vessels and storage tanks; (ii) Piping
    systems (including piping components such as valves); (iii) Relief and vent
    systems and devices; (iv) Emergency shutdown systems; (v) Controls (including
    monitoring devices and sensors, alarms, and interlocks) and, (vi) Pumps. . . .
    (4) Inspection and testing. (i) Inspections and tests shall be performed on
    process equipment.
    29 C.F.R. § 1910.119(j)(1), (4).
    3   The regulations underlying the citation for Item 12 provide:
    (1) Employers shall certify that they have evaluated compliance with the
    provisions of this section at least every three years to verify that the procedures
    and practices developed under the standard are adequate and are being
    followed.
    (2) The compliance audit shall be conducted by at least one person
    knowledgeable in the process.
    (3) A report of the findings of the audit shall be developed.
    (4) The employer shall promptly determine and document an appropriate
    response to each of the findings of the compliance audit, and document that
    deficiencies have been corrected.
    (5) Employers shall retain the two (2) most recent compliance audit reports.
    29 C.F.R. § 1910.119(o).
    3
    Case: 15-60443      Document: 00513815691        Page: 4     Date Filed: 12/29/2016
    No. 15-60443
    violations with penalties totaling $32,850. Secretary of Labor v. Delek, 
    2011 WL 12709990
    (OSHA Apr. 27, 2011) (Delek I). 4 Delek appealed six of the seven
    violations to the Occupational Safety and Health Review Commission (OSHRC
    or Commission). 5 The Commission unanimously vacated two violations and
    upheld a third. Secretary of Labor v. Delek, 
    2015 WL 1957889
    (OSHRC Apr.
    23, 2015) (Delek II). In a 2-1 split decision, the Commission also upheld the
    three remaining violations; Commissioner MacDougall dissented from the
    Commission’s decision affirming these three violations. 
    Id. at *16–27.
    The final
    three violations, each carrying a penalty of $6,300, are the subject of this
    appeal.
    II.
    We review the Commission’s factual findings to determine whether they
    are supported by substantial evidence in the record considered as a whole.
    MICA Corp. v. OSHRC, 
    295 F.3d 447
    , 449 (5th Cir. 2002). We review the
    Commission’s legal conclusions to determine whether they are “arbitrary,
    capricious, an abuse of discretion, or otherwise not in accordance with the law.”
    Trinity Marine Nashville, Inc. v. OSHRC, 
    275 F.3d 423
    , 427 (5th Cir. 2001); 5
    U.S.C. § 706(2)(A).
    We will defer to the agency’s interpretation of its own organic statute
    only if the text is ambiguous and the agency’s interpretation is reasonable.
    Chevron, USA, Inc. v. Nat. Res. Def. Council, Inc., 
    467 U.S. 837
    , 844 (1984);
    4  Though the ALJ affirmed the citation for Item 4, it did so only after deleting the
    allegations related “to the PHA team’s findings and recommendations from 1998 and 2005.”
    Delek I, 
    2011 WL 12709990
    , at *33.
    5 The Occupational Safety and Health Act divides administrative actions between the
    Secretary of Labor and the Occupational Safety and Health Review Commission. The
    Secretary has the responsibility of promulgating standards through rulemaking and bringing
    enforcement actions against employers. The Commission adjudicates appeals after an initial
    hearing before an administrative law judge. Martin v. OSHRC, 
    499 U.S. 144
    , 147–48 (1991).
    4
    Case: 15-60443     Document: 00513815691      Page: 5    Date Filed: 12/29/2016
    No. 15-60443
    Lari v. Holder, 
    697 F.3d 273
    , 278 (5th Cir. 2012). We will consider all the
    “traditional tools of statutory construction” before concluding that a statute is
    ambiguous. Contender Farms, LLP v. U.S. Dep’t of Agric., 
    779 F.3d 258
    , 269
    (5th Cir. 2015). If we determine that the text is clear, we owe no deference to
    the agency’s interpretation. City of Arlington v. FCC, 
    133 S. Ct. 1863
    , 1874
    (2013) (“Where Congress has established a clear line, the agency cannot go
    beyond it[.]”); 
    Lari, 697 F.3d at 278
    . If, however, we determine that the text is
    ambiguous, we will defer to the agency’s reasonable interpretation. 
    Lari, 697 F.3d at 278
    . Likewise, we will defer to an agency’s reasonable interpretation of
    its own regulations when the text of the regulation is ambiguous. Christensen
    v. Harris Cty., 
    529 U.S. 576
    , 588 (2000). “In situations in which the meaning
    of regulatory language is not free from doubt, the reviewing court should give
    effect to the agency’s interpretation so long as it is reasonable,” and it “sensibly
    conforms to the purpose and wording of the regulations.” 
    Martin, 499 U.S. at 150
    –51 (alterations omitted). If the regulation is clear, we will not defer.
    
    Christensen, 529 U.S. at 588
    ; see also Moore v. Hannon Food Serv., Inc., 
    317 F.3d 489
    , 495–96 (5th Cir. 2003).
    III.
    A.
    We first consider Delek’s challenge to the citations for Items 4 and 12.
    Items 4 and 12 relate to the process hazard analysis (PHA) and compliance
    audits required by Section 1910.119. That provision requires an employer to
    update and revalidate a PHA every five years. 29 C.F.R. § 1910.119(e)(6). A
    PHA requires the full-time labor of five to twelve skilled engineers and
    managers and generally takes four to six weeks. A PHA must “identify,
    evaluate, and control the hazards involved in the process.” 29 C.F.R.
    § 1910.119(e)(1). After a PHA is completed, the employer must, inter alia,
    “establish a system to promptly address” its findings, assure their timely
    5
    Case: 15-60443       Document: 00513815691         Page: 6    Date Filed: 12/29/2016
    No. 15-60443
    resolution, and document the manner in which they were resolved. 
    Id. § 1910.119(e)(5).
    Similarly, Section 1910.119 requires an employer to complete
    a compliance audit at least every three years. 
    Id. § 1910.119(o)(1).
    The
    compliance audit “verif[ies] that the procedures and practices developed under
    the standard are adequate and are being followed.” 
    Id. A compliance
    audit
    requires the efforts of eight to ten skilled employees and can take up to a week
    to perform. An employer must create a report after the audit and “promptly
    determine and document an appropriate response to each of the findings of the
    compliance audit, and document that deficiencies have been corrected.” 
    Id. § 1910.119(o)(3),
    (4). The employer must retain the records from its two most
    recent compliance audits. 
    Id. § 1910.119(o)(5).
           Delek argues that the citations for Items 4 and 12 are barred by the
    statute of limitations in 29 U.S.C. § 658(c). That section provides that “[n]o
    citation may be issued under this section after the expiration of six months
    following the occurrence of any violation.” 29 U.S.C. § 658(c). According to
    Delek, because the PHAs and the audit at the root of Items 4 and 12 took place
    in 1994, 1998, 1999, 2004, and 2005, the Secretary’s 2008 citations are outside
    the six-month statute of limitations. 6
    6 Delek also argues that the citations for Items 4 and 12 must be vacated because the
    violations underlying those Items were committed by Crown Central. According to Delek,
    Section 1910.119 does not authorize successor liability. Delek further argues that, even if
    Section 1910.119 does impose successor liability, the citations for Items 4 and 12 must still
    be vacated because the Commission did not undertake a successor liability analysis. By
    contrast, the Secretary contends that the successor liability doctrine is not implicated
    because Delek was cited for its own failure to resolve open PHA and audit findings after it
    purchased the plant from Crown Central. The Secretary also argues that Section 1910.119’s
    mandate is focused on the “process,” rather than a particular employer, and so Section
    1910.119’s requirements survive a change of ownership. Finally, the Secretary contends that
    Section 1910.119 is ambiguous and can reasonably be read to authorize successor liability.
    Because we vacate the citations for Items 4 and 12 based on Section 658(c)’s statute of
    limitations, we do not reach the successor liability issue.
    6
    Case: 15-60443     Document: 00513815691     Page: 7   Date Filed: 12/29/2016
    No. 15-60443
    Delek relies heavily on a decision by one of our sister circuits—AKM LLC
    dba Volks Constructors v. Secretary of Labor, 
    675 F.3d 752
    (D.C. Cir. 2012)—
    to support its statute of limitations argument. That case involved a set of
    citations issued by OSHA for violations of rules created under 29 U.S.C.
    § 657(c). 
    Id. at 755.
    Those rules required employers to “make, keep, and
    preserve” records of workplace injuries within a designated timeframe. 29
    U.S.C. § 657(c)(1). Volks was cited in November 2006 for its failure to create
    and maintain such records between 2002 and early 2006. 
    Volks, 675 F.3d at 753
    . The company argued that Section 658(c)’s six-month limitations period
    began to run when the violation occurred (i.e., when the prescribed deadline
    for creating the records had run) and that the citations were issued more than
    six months after this time. 
    Id. at 753.
    The Secretary, by contrast, argued that
    Volks’ failure to create the required records was a continuing violation of the
    regulations, such that the six-month period began anew each day until the
    close of the five-year period for which employers are required to keep records.
    
    Id. at 755.
          The D.C. Circuit rejected the Secretary’s continuing violations theory.
    
    Id. at 755–59.
    In particular, the court concluded that such a theory was
    inconsistent with the text of Section 658(c), which identifies an “occurrence” as
    the trigger for the statute of limitations. 
    Id. at 755–56.
    According to the court,
    an “occurrence” “clearly refers to a discrete antecedent event—something that
    ‘happened’ or ‘came to pass’ ‘in the past.’” 
    Id. at 755
    (quoting Nat’l R.R.
    Passenger Corp. v. Morgan, 
    536 U.S. 101
    , 109–10 & n.5 (2002)). The Secretary’s
    continuing violations argument was inconsistent with this understanding of
    an “occurrence” because the nature of a continuing violation is that it is
    ongoing—not a discrete, past event. 
    Id. 7 Case:
    15-60443       Document: 00513815691        Page: 8    Date Filed: 12/29/2016
    No. 15-60443
    Though we are not bound by the Volks decision, we find its reasoning
    persuasive. 7 Section 1910.119 requires an employer to “establish a system to
    promptly address the [PHA] team’s findings and recommendations,” to “assure
    that the recommendations are resolved in a timely manner,” and to “promptly
    determine and document an appropriate response to each of the findings of the
    compliance audit . . . .” 29 C.F.R. § 1910.119(e)(5), (o)(4). Just as a single
    violation “occurr[ed]” in Volks when the company failed to create the records
    within the prescribed time-period, so too a violation of subsections (e)(5) and
    (o)(4) “occur[s]” within the meaning of Section 658(c) when an employer does
    not “promptly” or “timely” do as Section 1910.119 directs. 8
    The Secretary reasserts here the “continuing violations” theory made in
    Volks, arguing that Delek’s failure to address the findings or recommendations
    at issue in Items 4 and 12 is a “continuing violation” and so Section 658(c)’s
    statute of limitations never began to run on those citations because they were
    never abated. We cannot accept this argument. To begin with, we note that
    applying a continuing violations theory in this case would conflict with the
    basic purposes of a statutory limitations period. “The general working
    presumption in federal civil and criminal cases is that a federal civil cause of
    action or criminal offense must have some statute of limitations and must not
    7 The Secretary argues that Volks only purported to apply to violations of record-
    making regulations promulgated under 29 C.F.R. Part 1904. This reading is implausible.
    While Volks certainly involved a violation of a record-making regulation, nothing in the
    majority opinion purports to limit its reach to Part 1904 record-making regulations.
    8 The Secretary has, on at least one occasion, taken the position that a response to
    PHA and audit recommendations is “timely” when it is done within “one to two years.” See
    Secretary of Labor v. BP Prods. N. Am., Inc., 
    2013 WL 9850777
    , at *37 (OSHRC Aug. 12,
    2013). We need not address this issue here, however, because the Secretary has not argued
    that the citations underlying Items 4 and 12 would be timely under the interpretation of
    Section 658(c) we now adopt, even if Section 1910.119’s references to “timely” or “prompt”
    action afforded an employer more than one or two years to resolve open PHA or audit
    recommendations.
    8
    Case: 15-60443     Document: 00513815691      Page: 9   Date Filed: 12/29/2016
    No. 15-60443
    allow suits to be brought forever and ever after the acts in question.” PHH
    Corp. v. Consumer Fin. Prot. Bureau, 
    839 F.3d 1
    , 50 (D.C. Cir. 2016); 
    id. (“As Chief
    Justice Marshall stated, allowing parties to sue ‘at any distance of time’
    would be ‘utterly repugnant to the genius of our laws. In a country where not
    even treason can be prosecuted after a lapse of three years, it could scarcely be
    supposed that an individual would remain forever liable to a pecuniary
    forfeiture.’” (quoting Adams v. Woods, 
    6 U.S. 336
    , 342 (1805))). The purpose of
    a statute of limitations is to “provide ‘security and stability to human affairs,’”
    Gabelli v. SEC, 
    133 S. Ct. 1216
    , 1221 (2013) (quoting Wood v. Carpenter, 
    101 U.S. 135
    , 139 (1879)), by promoting the “elimination of stale claims, and
    [promoting] certainty about a plaintiff’s opportunity for recovery and a
    defendant’s potential liabilities.” 
    Gabelli, 133 S. Ct. at 1221
    (quoting Rotella v.
    Wood, 
    528 U.S. 549
    , 555 (2000)).
    The Secretary’s proposed reading of Section 658(c) is, at best, in tension
    with these policies. Under the Secretary’s theory, OSHA would have authority
    to penalize an employer for failing to “promptly” or “timely” address PHA or
    audit recommendations or findings that arose twenty or more years prior—
    which is exactly what would occur in this case were we to accept the Secretary’s
    position. And as the Secretary has candidly acknowledged, his interpretation
    would authorize citations for unaddressed PHA or audit recommendations ad
    infinitum.
    At the same time, the Secretary’s reading of Section 658(c)—one that
    allows for citations decades after the “occurrence” of a violation—is at odds
    with the six-month limitations period in Section 658(c)’s text. Accepting the
    Secretary’s reading would effectively nullify the six-month limitations period
    that Congress deliberately wrote into Section 658(c) and thereby render that
    language meaningless in many cases. Our precedents, however, have
    repeatedly cautioned against interpreting statutes in such a manner if at all
    9
    Case: 15-60443    Document: 00513815691        Page: 10   Date Filed: 12/29/2016
    No. 15-60443
    possible. See, e.g., United States v. Wong Kim Bo, 
    472 F.2d 720
    , 722 (5th Cir.
    1972) (“[W]ords in statutes should not be discarded as ‘meaningless’ and
    ‘surplusage’ when Congress specifically and expressly included them . . . .”);
    accord 
    Volks, 675 F.3d at 756
    (“[W]e must be ‘hesitant to adopt an
    interpretation of a congressional enactment which renders superfluous
    another portion of that same law.’” (quoting United States v. Jicarilla Apache
    Nation, 
    564 U.S. 162
    , 185 (2011))).
    It is true that Volks left open the possibility that Section 658(c)’s statute
    of limitations “could be extended by the continuing violations concept” and
    identified safety violations as a possible candidate for the continuing violations
    theory. 
    Volks, 675 F.3d at 758
    (“Of course, where, for example a company
    continues to subject its employees to unsafe machines, or continues to send its
    employees into dangerous situations without appropriate training, OSHA may
    be able to toll the statute of limitations on a continuing violations theory since
    the dangers created by the violations persist.” (internal citations omitted)). The
    Secretary argues strenuously that the continuing violations theory applies to
    the directives in subsections (e)(5) and (o)(4).
    We, like the Volks court, do not decide whether OSHA may be able to use
    the continuing violations theory to toll Section 658(c)’s statute of limitations in
    cases involving continuing, unlawful risks to employee health and safety. Here,
    neither Section 1910.119(e)(5) nor (o)(4) mandates that the employer actually
    remedy the issues addressed in a PHA or audit recommendation. See 29 C.F.R.
    § 1910.119(e)(5), (o)(4). Subsection (e)(5) directs the employer to “address” the
    findings from a PHA and to “resolve[ ]” them in a timely manner. Likewise,
    subsection (o)(4) directs employers to “determine and document an appropriate
    response” to the audit compliance findings. As the Secretary acknowledges in
    his brief, “[a] PHA finding or recommendation is ‘resolved’ when the employer
    has adopted the item or has justifiably declined to do so.” Secretary Br. at 5 n.2
    10
    Case: 15-60443        Document: 00513815691          Page: 11      Date Filed: 12/29/2016
    No. 15-60443
    (emphasis added); see also 
    id. at 34
    (“Delek might have evaluated the findings
    and determined that they were not valid . . . .”); 
    id. at 41–42
    (“OSHA
    compliance guidance provides that an employer may justifiably decline to adopt
    a PHA finding or recommendation. Similarly, the cited audit report provision,
    29 C.F.R. § 1910.119(o)(4), says that the employer may determine an
    appropriate response to each audit finding. Thus, employers have discretion to
    reject items that they consider unmerited.” (citation omitted) (second emphasis
    in original)). And at oral argument, the Secretary acknowledged that “under
    the cited standards, the employer has the option of deciding that no resolution
    is necessary.” Oral Argument at 20:52–60, Delek Refining Ltd. v. OSHRC, No.
    15-60443 (emphasis added); 
    id. at 35:27–38
    (“The provision gives the employer
    the option of deciding once . . . audit or PHA findings and recommendations
    are made of saying, ‘Well, we don’t have to do anything further.’”). 9
    In   other     words,     while    a   PHA      or   audit     might     result    in   a
    recommendation—even a safety-related recommendation—an employer is
    under no obligation to actually implement that recommendation. This
    structure is quite unlike a safety regulation which commands the employer to
    actually remedy a safety hazard and maintain a workplace free of such
    hazards, and it distinguishes subsections (e)(5) and (o)(4) from the type of
    safety-related regulation for which a continuing violations theory might be
    appropriate. Accordingly, we cannot agree with the Secretary that the
    continuing violations theory applies here. 10
    In the ALJ’s opinion, each of the “open” items related to Item 4 are described as
    9
    “recommendation[s].” Delek I, 
    2011 WL 12709990
    , at *4–5.
    10 We emphasize that in rejecting this argument, we, like the D.C. Circuit, “express
    no opinion on whether some other violations, if any, could, for some other reason, be extended
    by the continuing violations concept.” 
    Volks, 675 F.3d at 758
    . We conclude only that, in light
    of the text of Section 658(c) as applied to the relevant portions of Section 1910.119(e) and (o),
    the continuing violations theory is not applicable.
    11
    Case: 15-60443        Document: 00513815691          Page: 12      Date Filed: 12/29/2016
    No. 15-60443
    We conclude, as did the D.C. Circuit, that Section 658(c) is clear, and so
    we do not defer to the Secretary’s interpretation. See 
    Volks, 675 F.3d at 755
    ,
    759. Accordingly, we hold that Section 658(c)’s six-month statute of limitations
    bars the citations for Items 4 and 12. We therefore vacate those citations.
    B.
    The Secretary also cited Delek under Item 8 for failing to inspect a piece
    of equipment known as the positive pressurization unit (PPU). Delek contends
    that this citation is unlawful because the PPU is not encompassed by the
    relevant regulations. Because this dispute involves the interpretation of a
    binding regulation promulgated by the agency, we defer to the agency’s
    interpretation if the text is ambiguous and the agency’s interpretation is
    reasonable. 
    Christensen, 529 U.S. at 588
    . Because we conclude that the
    relevant portions of Section 1910.119 are ambiguous and the Secretary’s
    interpretation is reasonable, we AFFIRM the citation for Item 8.
    Delek’s refinery contains a fluid catalytic cracking unit (FCCU). The
    process of fluid catalytic cracking involves “converting crude oil into usable
    fuels, such as gasoline, by a process that could release hazardous vapors.”
    Delek II, 
    2015 WL 1957889
    , at *7. This process is managed by Delek employees
    from the FCCU control room. 
    Id. The PPU
    is located in the FCCU control room,
    and “consists of an intake stack that draws in outside air and a fan that pulls
    the air into the control room.” Delek I, 
    2011 WL 12709990
    , at *10. In so doing,
    the PPU maintains “positive pressure” inside the FCCU control room, thereby
    Nor does our decision cast doubt upon the application of the discovery rule to Section
    658(c). See, e.g., Austin Indus. Specialty Servs., L.P. v. OSHRC, 
    765 F.3d 434
    , 442 (5th Cir.
    2014). The rule states that “OSHA may cite a party for an uncorrected violation of applicable
    regulations within six months from the time that OSHA discovers, or should have discovered,
    the facts establishing the violation.” 
    Id. at 442.
    The Secretary here did not raise the discovery
    rule to justify the timing of the citations underlying Items 4 and 12.
    12
    Case: 15-60443       Document: 00513815691       Page: 13    Date Filed: 12/29/2016
    No. 15-60443
    “keep[ing] harmful or hazardous vapors from entering the control room.” 11 
    Id. at *9,
    *10 (quotation marks omitted). Without the PPU, hazardous vapors
    could enter the FCCU control room and harm Delek employees managing the
    fluid catalytic cracking process or react with wiring in the control room to cause
    a catastrophic explosion. Delek II, 
    2015 WL 1957889
    , at *7; Delek I, 
    2011 WL 12709990
    , at *15. The PPU also contains two sensors. One detects whether the
    FCCU control room is pressurized and triggers an alarm that indicates when
    it is not. Delek I, 
    2011 WL 12709990
    , at *10; Delek II, 
    2015 WL 1957889
    , at *7.
    The other detects the presence of combustible gas and will shut down the
    intake stack to prevent the gas from entering the control room if such gas is
    detected. 12 
    Id. The parties
    do not dispute where the PPU is located, what it consists of,
    or what it does. They instead dispute whether the PPU is subject to the
    inspection requirements of 29 C.F.R. § 1910.119(j). Section 1910.119 applies to
    “a process which involves a Category 1 flammable gas” and further defines
    “process” as “any activity involving a highly hazardous chemical including any
    use, storage, manufacturing, handling, or the on-site movement of such
    chemicals, or combination of these activities.” 29 C.F.R. § 1910.119(a)(1)(ii),
    (b). Section 1910.119(j) requires employers to “establish and implement
    written procedures to maintain the on-going integrity of process equipment”
    and to perform “[i]nspections and tests . . . on process equipment.” 
    Id. § 1910.119(j)(2),
       (4)(i).   Section   1910.119(j),   in   turn,   defines   “process
    equipment” as “the following”: “(i) Pressure vessels and storage tanks; (ii)
    Piping systems (including piping components such as valves); (iii) Relief and
    11 Delek’s own “Mechanical Integrity Manual” describes the purpose of “control room
    pressurization” as “keeping harmful or hazardous vapors from entering.”
    12 As the ALJ noted, several Delek employees testified that the PPU serves an
    important safety function. See Delek I, 
    2011 WL 12709990
    , at *11, *13.
    13
    Case: 15-60443     Document: 00513815691      Page: 14   Date Filed: 12/29/2016
    No. 15-60443
    vent systems and devices; (iv) Emergency shutdown systems; (v) Controls
    (including monitoring devices and sensors, alarms, and interlocks) and, (vi)
    Pumps.” 
    Id. § 1910.119(j)(1)(i)–(vi).
          The Secretary argues that the PPU is subject to Section 1910.119(j)’s
    inspection regime because: (1) the PPU is an integral part of the FCCU, which
    is a “process” under Section 1910.119(b); and (2) the PPU is “process
    equipment” under Section 1910.119(j). We will address these issues in turn.
    1.
    The Commission concluded that the PPU fits within Section
    1910.119(b)’s definition of “process” because “the PPU is an integral part of the
    overall [FCCU] ‘process.’” Delek II, 
    2015 WL 1957889
    , at *7. On appeal, the
    Secretary urges us to accept this determination. While both parties agree that
    the FCCU is a “process” within the meaning of Section 1910.119(b), they
    dispute whether the PPU is a part of the FCCU process.
    We conclude, based on the undisputed facts as to the PPU’s function,
    that the Commission reasonably determined that the PPU is part of the overall
    FCCU “process” and is therefore covered by Section 1910.119(b). As the
    Commission indicated, the PPU serves an important function vis-à-vis the
    fluid catalytic cracking process by ensuring maintenance of positive air
    pressure within the FCCU control room and thereby preventing the flow of
    hazardous chemicals or vapors into the control room. In so doing, the PPU
    protects the Delek employees within the FCCU control room who are managing
    the fluid catalytic cracking process, and, in turn, plays a role in protecting the
    integrity of that process. Further, by preventing the flow of hazardous
    chemicals into the FCCU, the PPU prevents hazardous vapors from interacting
    with the wiring in the FCCU and potentially causing an explosion. In short,
    the PPU does far more than serve as a mere ventilation system; it plays an
    14
    Case: 15-60443      Document: 00513815691    Page: 15   Date Filed: 12/29/2016
    No. 15-60443
    important part in ensuring the integrity of the fluid catalytic cracking process
    itself.
    Delek argues, however, that the PPU cannot be part of a “process”
    because it does not fit within the definition of “process” in 29 C.F.R.
    § 1910.119(b). Specifically, Delek contends in its briefing that the activities
    listed in the definition of process—“use, storage, manufacturing, handling, or
    [ ] on-site movement”—show that a “process” is limited to the “containment of
    the highly hazardous chemical and the actual manufacturing of a product.” As
    Delek correctly notes, the PPU does not contain any highly hazardous
    chemicals, nor does it use, store, manufacture or handle such chemicals—at
    least not in the ordinary sense of those terms. Cf. 29 C.F.R. § 1910.119(b).
    However, the Commission did not conclude—and the Secretary does not
    argue on appeal—that the PPU itself is a “process.” As noted, the Commission
    concluded that “the PPU is an integral part of the overall FCC unit ‘process.’”
    Delek II, 
    2015 WL 1957889
    , at *7 (emphasis added). As a result, the PPU need
    not independently constitute a “process” under Section 1910.119(b). But in any
    event, to the extent Section 1910.119(b)’s definition is pertinent to defining the
    parameters of a covered “process,” we do not agree that Section 1910.119(b)’s
    definition necessarily excludes the PPU. Section 1910.119(b) defines “process”
    broadly to encompass “any activity involving a highly hazardous chemical
    including any use, storage, manufacturing, handling, or the on-site movement
    of such chemicals . . . .” 29 C.F.R. § 1910.119(b) (emphasis added). It is
    undisputed that the PPU operates to detect the presence of highly hazardous
    chemicals and gases and to prevent them from entering the FCCU. In
    performing this “activity,” the PPU undoubtedly “involv[es]” the very
    chemicals and gases that it detects and prevents from entering the FCCU
    control room.
    15
    Case: 15-60443    Document: 00513815691       Page: 16   Date Filed: 12/29/2016
    No. 15-60443
    Delek argues, however, that the PPU does not fit within any of the
    specific activities listed in the definition of “process”—“use, storage,
    manufacturing, handling, or . . . on-site movement” of such chemicals. 29
    C.F.R. § 1910.119(b). But the use of the term “including” within Section
    1910.119(b)’s definition indicates that these forms of “involv[ement]” with
    highly hazardous chemicals are not an exhaustive listing. See ANTONIN SCALIA
    & BRYAN A. GARNER, READING LAW: THE INTERPRETATION OF LEGAL TEXTS 132
    (Thomas/West 2012) (“[T]he word include does not ordinarily introduce an
    exhaustive list . . . .”). Thus, even assuming that the PPU’s involvement with
    highly hazardous chemicals does not fit within one of the examples listed in
    Section 1910.119(b), that fact would not clearly exclude the PPU from the
    definition of “process” in Section 1910.119(b).
    Delek further argues that the PPU “is simply too far removed from the
    [FCCU] to be considered part of the PSM-covered ‘process’ . . . .” For this
    argument, Delek relies on two interpretive letters from OSHA, one from
    January 2008 and the other from February 1997. See OSHA Std. Interp.
    1910.119 (D.O.L.), 
    2008 WL 2565070
    (Jan. 31, 2008) (2008 OSHA Letter);
    OSHA Std. Interp. 1910.119 (D.O.L.), 
    1997 WL 33798325
    (Feb. 28, 1997) (1997
    OSHA Letter). According to Delek, these letters indicate that equipment is part
    of a “process” only “if that system has a ‘direct involvement in the overall
    functioning of the process’ and ‘can affect or cause a release.’”
    The 2008 OSHA Letter, however, makes it clear that utility systems (the
    type of equipment at issue in that letter) are within the “scope . . . of the PSM
    standard” if they are “use[d] . . . to control/prevent and mitigate catastrophic
    releases of [highly hazardous chemicals].” 2008 OSHA Letter, 
    2008 WL 2565070
    , at *3 (emphasis added). As indicated, the PPU plays a role in
    mitigating the release of highly hazardous chemicals by preventing their
    16
    Case: 15-60443      Document: 00513815691        Page: 17    Date Filed: 12/29/2016
    No. 15-60443
    movement into the FCCU control room. 13 Likewise, the 1997 OSHA Letter
    indicates that a “process” encompasses equipment, even though that
    equipment does not contain highly hazardous chemicals, if it “could . . .
    interfere with mitigating the consequences of such a release.” See 1997 OSHA
    Letter, 
    1997 WL 33798325
    , at *1. This statement, however, is broader than
    Delek’s claim that equipment may be part of a “process” only if it has “a ‘direct
    involvement in the overall functioning of the process’ and ‘can affect or cause
    a release.’” Thus, we do not believe either of the prior OSHA Letters limited
    the scope of a “process” in the manner that Delek asserts, or necessarily
    forecloses the Secretary’s interpretation here. 14
    Accordingly, we conclude that the Secretary reasonably interpreted
    Section 1910.119(b) in determining that the PPU is part of a “process.”
    2.
    The Secretary further contends that the PPU is “process equipment”
    subject to Section 1910.119(j)’s inspection regime. As noted, Section 1910.119(j)
    supplies an exhaustive list of categories that constitute “process equipment”:
    “(i) Pressure vessels and storage tanks; (ii) Piping systems (including piping
    components such as valves); (iii) Relief and vent systems and devices; (iv)
    Emergency shutdown systems; (v) Controls (including monitoring devices and
    sensors, alarms, and interlocks) and, (vi) Pumps.” 29 C.F.R. § 1910.119(j)(1)(i)–
    13The Commission likewise considered the 2008 OSHA Letter in the context of Delek’s
    argument that equipment can only be part of a “process” if it contains highly hazardous
    chemicals. See Delek II, 
    2015 WL 1957889
    , at *8.
    14Delek also seems to argue that there was no real concern that vapors would enter
    the FCCU. However, Delek concedes that the PPU exists to detect the presence of
    combustible gases and to prevent their entrance into the FCCU.
    17
    Case: 15-60443        Document: 00513815691           Page: 18     Date Filed: 12/29/2016
    No. 15-60443
    (vi). The Secretary argues—as the Commission determined—that the PPU is
    a “control” because it contains “sensors” and “alarms.” 15
    We agree. To begin with, we do not believe the term “control” in Section
    1910.119(j) clearly excludes the PPU. That term is not elsewhere defined in
    Section 1910.119, and the regulation provides a non-exhaustive list of items
    that qualify as controls. See 29 C.F.R. § 1910.119(j)(1)(v) (“Controls (including
    monitoring devices and sensors, alarms, and interlocks”) (emphasis added));
    see SCALIA & 
    GARNER, supra, at 132
    (“[T]he word include does not ordinarily
    introduce an exhaustive list . . . .”). We therefore find that there is sufficient
    ambiguity in the text of Section 1910.119(j) to accord deference to the
    Secretary’s interpretation of “control” if it is reasonable.
    We conclude that it is. Section 1910.119(j) lists “sensors” and “alarms” as
    examples of “controls.” See 29 C.F.R. § 1910.119(j)(1)(v). As noted, the PPU
    contains two sensors. The first sensor measures whether the FCCU control
    room has positive pressure, and this sensor is connected to, and triggers, an
    alarm when the control room is not fully pressurized. The second sensor detects
    15  The Commission also concluded that the PPU was a “control” because it “is an
    integral part of the FCC unit control room.” Delek II, 
    2015 WL 1957889
    , at *8. Because we
    conclude, based on Section 1910.119(j)’s text, that the Secretary reasonably determined that
    the PPU is process equipment, we need not reach this other ground.
    The Secretary also argues that the PPU is process equipment because Delek “deemed”
    it to be so. Again, because we conclude that the PPU is process equipment based on the text
    of Section 1910.119(j), we do not decide this issue. We note, however, that it is unlikely we
    would accept this argument if we did consider it. The Secretary relies on a portion of OSHA’s
    summary and explanation of Section 1910.119(j), which states that “if an employer deems
    additional equipment to be critical to a particular process, that employer should consider that
    equipment to be covered by [Section 1910.119(j)] and treat it accordingly.” OSHA, Process
    Safety Management of Highly Hazardous Chemicals; Explosives and Blasting Agents, 57 Fed.
    Reg. 6356-01, 
    1992 WL 30969
    , at *6389 (Feb. 24, 1992). But the Secretary does not direct us
    to any language in the text of Section 1910.119 itself to suggest that OSHA may cite an
    employer for failing to inspect equipment not covered by subsection (j) just because the
    employer believed that equipment should be covered by subsection (j). To the contrary,
    subsection (j)’s text indicates that its list of process equipment is exhaustive. See 29 C.F.R.
    § 1910.119(j)(1) (“Paragraphs (j)(2) through (j)(6) of this section apply to the following process
    equipment . . . .” (emphasis added)).
    18
    Case: 15-60443        Document: 00513815691          Page: 19     Date Filed: 12/29/2016
    No. 15-60443
    the presence of combustible gas and shuts down the PPU intake stack when
    combustible gas is detected. Delek II, 
    2015 WL 1957889
    , at *7; Delek I, 
    2011 WL 12709990
    , at *10. Thus, because the PPU contains multiple sensors and
    an alarm that are critical to its function of ensuring that combustible vapors
    do not enter the FCCU control room, we conclude that the Secretary reasonably
    concluded that the PPU is a “control” within the meaning of Section
    1910.119(j). 16
    Delek raises several objections in its briefs to reading “control” to
    encompass the PPU. First, Delek argues that the PPU cannot constitute a
    “control” because Section 1910.119 is concerned with “containment of
    chemicals before release,” while the PPU “merely interrupts the spread of
    [hazardous] chemicals from one room to the next after the release has already
    occurred.” Delek’s description of the Process Safety Management Standard,
    however, is inconsistent with the “Purpose” statement at the beginning of
    Section 1910.119 itself, which indicates that these standards are designed to
    “prevent[] or minimiz[e] the consequences of catastrophic releases of toxic,
    reactive, flammable, or explosive chemicals.” See 29 C.F.R. § 1910.119
    (Purpose). Preventing the flow of hazardous chemicals into the FCCU control
    room after their release is undoubtedly a means of “minimizing the
    consequences” of such a release. 
    Id. Second, Delek
    notes that the Preamble to the Process Safety
    Management Standard indicates that “process equipment” must have “‘a
    significant impact on the safety of a process that is covered by [the PSM
    Standard].’” According to Delek, because the FCCU’s process activities could
    16 Because Section 1910.119(j)’s definition of control explicitly references “alarms” and
    “sensors” as examples of “controls,” we do not agree with the amici that interpreting Section
    1910.119(j) to encompass the PPU deprives employers of sufficient notice of the potential
    scope of Section 1910.119(b) and (j).
    19
    Case: 15-60443       Document: 00513815691          Page: 20     Date Filed: 12/29/2016
    No. 15-60443
    continue even if the PPU failed, it cannot be considered “process equipment.”
    Again, we do not find this argument persuasive. The PPU does serve a safety
    function by preventing the flow of released hazardous chemicals into the FCCU
    control room. In so doing, the PPU not only protects the Delek employees
    within that control room, but also protects the integrity of the FCCU process
    itself, which is managed by those employees. 17
    Finally, Delek and the amici argue that interpreting “control” in Section
    1910.119(j) to encompass the PPU would lead to absurd results because a door,
    window, wall, or anything else that “‘interrupts the circulation of already-
    released hazardous chemicals’” would constitute “process equipment.” This
    slippery slope argument, however, ignores the fact that the PPU’s purpose is
    to prevent the flow of hazardous chemicals into the FCCU control room. While
    a door, window, or wall may have this effect incidentally, they are not designed
    for this purpose as is the PPU, nor are they equipped with sensors and alarms
    to detect the presence of hazardous gases and to measure whether the FCCU
    control room is properly pressurized. Thus, we disagree with Delek and the
    amici that upholding the Secretary’s interpretation of Section 1910.119(b) and
    (j) sweeps equipment only tangentially related to a covered process into the
    definitions of “process” and “process equipment,” or that it brings non-
    equipment, such as a door or window, into the ambit of those subsections.
    We therefore hold that the relevant provisions of Section 1910.119 do not
    clearly exclude the PPU from being a part of a “process” or “process
    17  Delek also argues that “the Commission failed to see the distinction between
    independently possessing controls and being a control for a PSM-covered ‘process.’” According
    to Delek, “[t]he fact that the PPU has sensors does not bring it within [Section
    1910.119(j)(4)(i)] because the controls have nothing to do with the FCC unit.” For the reasons
    already given, we have concluded that the PPU can reasonably be viewed as a part of the
    FCCU process, and so its operation as a “control” under Section 1910.119(j) is for a covered
    “process.”
    20
    Case: 15-60443        Document: 00513815691           Page: 21     Date Filed: 12/29/2016
    No. 15-60443
    equipment.” Because the Secretary’s interpretation is reasonable, we defer to
    that interpretation. 18
    IV.
    We hold that the citations for Items 4 and 12 are barred by Section
    658(c)’s six-month statute of limitations. We also hold that the Secretary
    reasonably determined that the PPU is covered by 29 C.F.R. § 1910.119.
    Accordingly, we VACATE the citations for Items 4 and 12 and AFFIRM the
    citation for Item 8, which amounts to $6,300.
    18  Delek argues vigorously that the Commission erred by declining to consider
    testimony of its experts as to whether the PPU was a part of “process” and constituted
    “process equipment,” while not similarly declining to consider the testimony of the
    Secretary’s expert on the same subject. See Delek II, 
    2015 WL 1957889
    , at *7 n.7. We agree
    with Delek that the Commission had no justifiable reason for declining to consider Delek’s
    expert’s testimony while not doing the same for the Secretary’s expert’s testimony. On appeal,
    the Secretary did not attempt to defend the Commission’s action in this regard.
    However, we conclude that the Commission’s error was harmless, and so we do not
    reverse on this basis. See 5 U.S.C. § 706 (“[D]ue account shall be taken of the rule of
    prejudicial error.”); United States v. Johnson, 
    632 F.3d 912
    , 930 (5th Cir. 2011) (“‘In
    administrative law, as in federal civil and criminal litigation, there is a harmless error rule.’”
    (quoting Nat’l Ass’n of Home Builders v. Defs. of Wildlife, 
    551 U.S. 644
    , 659–60 (2007)). Upon
    reviewing the Commission’s decision, it is clear that the Commission based its conclusion on
    the text of Section 1910.119(b) and (j) and the undisputed facts regarding the PPU’s function.
    See Delek II, 
    2015 WL 1957889
    , at *6–9. The Commission’s decision does not appear to rely
    in any way on the testimony of the Secretary’s expert in support of its decision to affirm the
    citation for Item 8, and its decision is consistent with both parties’ factual descriptions of the
    PPU. As a consequence, we conclude that the Commission’s error “‘clearly had no bearing on
    the procedure used or the substance of decision reached,’” and so its error was harmless.
    Sierra Club v. U.S. Fish & Wildlife Serv., 
    245 F.3d 434
    , 444 (5th Cir. 2001) (quoting U.S.
    Steel Corp. v. EPA, 
    595 F.2d 207
    , 215 (5th Cir. 1979)).
    21